Over-the-Top Cementing Technique in Cup-Cage Reconstructions
DOI:
https://doi.org/10.12974/2313-0954.2017.04.01.4Keywords:
Cup-cage, discontinuity, cement, screws.Abstract
Cup-cage constructs have been used for acetabular reconstruction in the setting of severe defects as well as pelvic discontinuity. This construct consists of a porous tantalum shell augmented with screws with an ilio-ischial cage that is placed over it. The superior flange of the cage is then affixed into the ilium with screws while the inferior flange is impacted into the ischial bone. A polyethylene cup is then cemented into the cage to complete the construct. The over-the-top cementing technique extends the extruded cement mantle from the polyethylene cup impaction over the superior flange creating a buttress construct to prevent screw back-out. In the setting of these complex cases this buttress effect can possibly improve the strength of the cup-cage construct.
References
Trousdale RT and Lewallen DG. Cup-cage construct provides options for large defect acetabular revisions. Orthopedics Today 2014.
Noiseux M, Lewallen DG, Kellet C and Gross AE. Results of a porous coated cup-cage construct in complex revision surgery with severe bone loss. Paper presented at the AAOS Annual Meeting; 2007, San Diego, CA.
Boulton CL, Kim H, Shah SB, Ryan SP, Metzger TA, et al. Do locking screws work in plates bent at holes? J Orthop Trauma 2014; 28(4): 189-94. https://doi.org/10.1097/BOT.0b013e3182a73a77
Kosashvili Y, Backstein D, Safir O, Lackstein D and Gross AE. Acetabular revision using an anti-protrusion (ilio-ischial) cage and trabecular metal acetabular component for severe acetabular bone loss associated with pelvic discontinuity. J Bone Joint Surg Br 2009; 91(7): 870-876. https://doi.org/10.1302/0301-620X.91B7.22181
Abolghasemian M, Tangsaraporn S, Drexler M, Barbuto R, Backstein D, et al. The challenge of pelvic discontinuity: cupcage reconstruction does better than conventional cages in mid-term. Bone Joint J 2014; 96-B(2): 195-200. https://doi.org/10.1302/0301-620X.96B2.31907
Amenabar T, Rahman WA, Hetaimish BM, Kuzyk PR, Safir OA, et al. Promising mid-term results with a cup-cage construct for large acetabular defects and pelvic discontinuity. Clin Orthop Relat Res 2016; 474: 408-414. https://doi.org/10.1007/s11999-015-4210-4
Solomon LB, Abrahams JM, Callary SA and Howie D. Stability of cup-cage construct for treatment of pelvic dissociation measured by radiostereometric analysis. Paper presented at the AAOS Annual Meeting 2016, Orlando, FL.
Laflamme GY, Alami GB and Zhim F. Cement as a locking mechanism for screw heads in acetabular revision shells – a biochemical analysis. Hip Int 2008; 18(1): 29-34.
Le TT, Vo HV and Webb LX. Investigation of Kryptonite TM bone cement in hybrid screw configurations of locking plate humeral midshaft fixation: A study of surrogate bone model. J Orthop 2016; 13(3): 157-61. https://doi.org/10.1016/j.jor.2016.03.002
Vallier HA, Hennessey TA and Sontich JK. Failure of LCP condylar plate fixation in the distal part of the femur. A report of six cases. J Bone Joint Surg Am 2006; 88: 846-853. https://doi.org/10.2106/JBJS.E.00543
Strauss EJ, Schwarzkopf R, Kummer F and Egol KA. The current status of locked plating: The good, the bad, and the ugly. J Orthop Trauma 2008; 22(7): 479-86. https://doi.org/10.1097/BOT.0b013e31817996d6
Ezzet KA. Cementing acetabular sockets into metal-backed acetabular components and antiprotrusio cages: a technical tip. J Arthroplasty 2007; 22(4): 609-11. https://doi.org/10.1016/j.arth.2006.12.053